Parameter list
7.2 Parameter list
Parameter
Function
Note:
The Hammer Start boost is calculated in the same way as Continuous Boost (P1310). As the stator re-
sistance is used, the calculated voltage is only accurate at 0Hz. Thereafter, it will vary in the same way as
Continuous Boost.
Setting in P0640 (motor overload factor [%]) limits the boost.
P3358[0...2]
Number of hammer
cycles
The number of times the hammer start boost level (P3357) is applied.
Index:
See P3350
P3359[0...2]
Hammer on time [ms]
Time for which the additional boost is applied for each repetition.
Index:
See P3350
Dependency: The time must be at least 3 x motor magnetization time (P0346).
P3360[0...2]
Hammer off Time [ms]
Time for which the additional boost is removed for each repetition.
Index:
See P3350
Note:
During this time, the boost level drops to the level defined by P1310 (continuous boost).
P3361[0...2]
Blockage clearing fre-
quency [Hz]
Defines the frequency at which the inverter runs in the opposite direction to the setpoint during the block-
age clearing reverse sequence.
Index:
See P3350
P3362[0...2]
Blockage clearing re-
verse time [s]
Sets the time for which the inverter runs in the opposite direction to the setpoint during the reverse se-
quence.
Index:
See P3350
P3363[0...2]
Enable rapid ramp
Selects whether the inverter ramps to, or starts directly from, the blockage clearing frequency (P3361).
0
1
Index:
See P3350
Note:
If P3363 = 1, the output jumps to the reverse frequency - this introduces a "kicking" effect which helps to
clear the blockage.
P3364[0...2]
Number of blockage
clearing cycles
The number of times the blockage clearing reversing cycle is repeated.
Index:
See P3350
r3365
CO/BO: Status word:
super torque
Shows the operational status of the Super Torque function, while active.
Bit
00
01
02
276
Range
1 - 10
0 - 1000
0 - 1000
0.0 - 550.0
0.0 - 20.0
0 - 1
Disable rapid ramp for blockage clearing
Enable rapid ramp for blockage clearing
1 - 10
-
Signal name
Super Torque Active
Super Torque Ramping
Super Torque Boost On
Factory
Can be
default
changed
5
C, T
300
T
100
T
5.0
T
5.0
T
0
T
1
T
-
-
Operating Instructions, 09/2014, A5E34559884
Scaling
Data
Data
set
type
-
-
U16
-
-
U16
-
-
U16
-
-
Float
-
-
Float
-
-
U16
-
-
U16
-
-
U16
1 signal
0 signal
Yes
No
Yes
No
Yes
No
SINAMICS V20 Inverter
Acc.
Level
2
2
2
2
2
2
2
2