Section 6: Specifications
Lamp (DC)
Max. operating voltage
Max. start-up voltage
Max. current consumption
Max. power consumption
Connector type
6.5.2 7 kW 3-Phase Ballast
Input Ratings
Inrush current (max.)
Power consumption (max.)
Current rating (continuous) of 3-phase AC input at
breaker/power switch
Breaker/power switch rating
Ballast Output to Projection Head
Operating voltage range
Start-up voltage (open current)
Operating current range
Ripple
Control ports

6.6 Lamps

Replace before times:
NOTES: 1)
Current range shown includes "over-drive", which is 10% more than the original lamp rating.
2)
Optimized brightness requires CDXL lamp.
Stand-by lamp power level for 4.5/6.0
Stand-by lamp power level 2.0/3.0
Motorized adjustment of position
6-6
(38-814001-51)
note: excluding lamp
Ballast
CXL/CDXL Lamps
CXL/CDXL-20 (2.0)
CXL/CDXL-30 (3.0)
3-Phase 7 kW
CXL/CDXL-45 (4.5)
CXL/CDXL-60 (6.0)
Type
46 VDC
155 VDC
180 A
6600 W
Female CAM Lock receptacle (+red)
Male CAM Lock receptacle (–black)
200-230 V 3~ +PE, 24 A, 50-60 Hz/380-415V 3~ +N +PE,
16 A, 50-60 Hz
<50 A
14.4 kVA (9.1 kW), all regions
30 A, all regions
50 A
18-46 VDC
125-155 VDC
50-180 A
1% max @ 25°C
Refer to
6.4.7 Control Port (From Ballast)
Ports.
Lamp Life ( hrs.)
(kW)
Xenolite
60% of lamp's maximum current rating
75% of lamp's maximum current rating
3-axis, 0.25" range for each
and
6.4.8 Ballast
3000
2000
600
600
®
Roadie HD+35K User Manual