IP Address. Enter a valid and unique IP address for use on the network to which the projector is currently
connected. Upon the next power-up, this address will overwrite any previous IP address such as the projector's
factory-defined default (0.0.0.0), or one that has been assigned by a DHCP server or other user. An IP address
entered here remains in effect until it is changed again.
NOTE:
Make sure the projector is connected to the network before changing its IP address. Make sure to re-boot.
Port. On some Ethernet networks, firewall restrictions may require that the port number of the projector be
changed from its default of 3002. If so, enter a new valid port number here. . It is highly recommended not to
use a port# below 1024, as these ports are typically reserved by common IP applications.
Subnet Mask and Default Gateway. The Subnet Mask and Default Gateway are automatically assigned when
DHCP is enabled. If a static IP is being used, the IP must be assigned first since the subnet mask is estimated
by the projector after the IP is entered. The Default Gateway is an optional router device used to send and
receive data outside the subnet.
ArtNet Interface Settings Secondary Menu
ArtNet is an Ethernet communication protocol that was developed by Artistic Licence. It is used for controlling
lighting/staging equipment from a lighting console or PC application. It is based on the popular DMX512
control protocol.
ArtNet Subnet. This is the highest level address for a device. Typically it is set to 0.
ArtNet Universe. Each packet of data is broadcasted to all devices plugged into a universe (up to 512 devices/
channels).
ArtNet Channel. There are 512 channels per universe. This control allows you to specify the starting channel
for this projector.
ArtNet Advanced Mode. When this setting is enabled, each projector listens for data on 64 channels starting
with the base channel. When
squeeze more devices per universe when the projector uses fewer channels.
NOTE:
The additional 54 functions are not currently implemented and are reserved for future use.
ArtNet Base Channel. When advanced mode is enabled, the projector listens to data on 64 consecutive
channels, or 10 consecutive channels when
that come on either 10 or 64 consecutive channels beginning with the 'base channel' defined here. The requests
implement the following functions:
DMX Channel
Base
Base + 1
Base + 2
Base + 3
Base + 4
Base + 5
3-46
Advanced
mode is not in use, the projector only listens on 10 channels. You can
Function
Shutter
0 – 64
65 – 192
193 – 255
Slider Lock
0 – 254
255
Input *
1 – 8
Channel *
1-99
Lens – Vertical * †
0
1 – 254
255
Lens – Horizontal *
0
1 – 254
255
Advanced
mode is not enabled. The projector processes requests
Value
Open
No Action
Closed
Locked
Unlocked *
Input #
Channel #
Lens Down
Stop
Lens Up
Lens Right
Stop
Lens Left
Roadie HD+35K User Manual