Christie Roadie HD+35K User Manual page 146

Hide thumbs Also See for Roadie HD+35K:
Table of Contents

Advertisement

Section 3: Operation
Code
GENERAL
12
13
14
15
16
17
18
LAMP / BALLAST
20
22
26
27
28
29
2C
SENSORS for COOLING
40
46
48
49
4C
4D
4E
4F
FANS (note: there are no Fans 1 or 2 in this projector)
53
54
55
56
57
58
3-80
Table 3.9 System Error Codes
Software error. Contact dealer/factory.
CRC error in flash ROM. Download new software.
Engineering-only programming is complete. Call Christie, replace TIPM.
Attempting to download s/w code without being in boot mode
Invalid interrupt. Power off/on. If persists, contact dealer/factory.
User has forced system to stay in boot mode
Attempting to program boot mode without jumper
The lamp is unexpectedly on (likely a ballast and/or wiring problem)
One or more high-current lamp cables is not connected
Lamp door is open (interlock)
Lamp cannot ignite
Lamp has turned off unexpectedly
Lamp ballast is overheated
Lamp communications fault; ballast is not detected
Lamp has shut down due to fan failure
The red TEC (DMD) has overheated
The blue TEC (DMD) has overheated
The prism has overheated
Projector has shut down due to critical error
Integrator has overheated
Inadequate lamp air intake rate (interlock)
Inadequate air exhaust rate (interlock)
Fan 3 has failed (side [rear] intake fan)
Fan 4 has failed (side [front] intake fan)
Fan 5 has failed (lamp exhaust fan)
Fan 6 has failed (LAD fan)
Fan 7 has failed (card cage fan)
Fan 8 has failed (heat exchanger fan — for liquid cooling system)