Confirm that the ballast's three-phase status lights are ON and that the adjacent voltmeter displays an
acceptable AC level for your ballast, and region. Refer to
the ballast's breaker/power switch to the ON position.
NOTE:
The ballast's internal fan is the only indication whether or not the breaker/power switch is ON. Lights
on the ballast indicate only that the ballast is plugged in.
Head-to-AC
Connect the Christie-supplied IEC 320 (220V) 15-amp line cord to your AC supply. Do not substitute
other cords. Input power required is 200 - 240 VAC (nominal), 50/60 Hz @ 3A for 208V. Refer to
2-4.
Roadie HD+35K User Manual
020-100340-02 Rev. 1 (01-2010)
NOTE: Internal
Incoming Line Voltage
4.
Breaker/Power
Switch in ON position
3-phase
3.
Check
status
Voltmeter (400V)
Figure 2-3 Ballast Connection and Switch On
Section 6 Specifications
switch setting must match AC available at the site.
Interlocks
Control
6' line cord
Connect to AC supply:
2.
• 200 VAC in N. America
• 208 VAC in Japan
• 380/400/415 VAC in Europe