Filter Replacement Procedure - Christie Roadie HD+35K User Manual

Hide thumbs Also See for Roadie HD+35K:
Table of Contents

Advertisement

14. Adjust lamp position.
From the Lamp menu, go to the LampLOC secondary menu and perform a "Do Auto" adjustment. It takes
a minute or two as internal motors and sensors determine the ideal placement of the lamp. Proper
LampLOC ensures maximum brightness, with the lamp well-centered in the reflector and distanced
correctly from the rest of the illumination system. Refer to
(LampLOC™)
15. Record the serial number of the new lamp, as follows:
a. In the Lamp menu, select "Change Lamp".
b. In the Lamp S/N text box, enter the serial number.
c. Press E
to log time for the new lamp.

4.4.2 Filter Replacement Procedure

Replace the air filter whenever the lamp module is replaced, or more frequently if operating the projector in a
dusty or dirty environment. Check monthly in all cases. The filter is located on the lamp side of the projection
head, near the front.
Removing the Air Filter
1. By pressing and holding the P
2. Once OFF, allow the fans to run at least 10 minutes for cooling the lamp.
3. Set the breaker/power switch to OFF.
4. To open/remove the filter compartment door, loosen 2 corner screws using a flat screwdriver, and lift off
door.
Roadie HD+35K User Manual
020-100340-02 Rev. 1 (01-2010)
for details.
NTER
on either keypad to record the number and to reset the lamp timer. The timer now begins
Switch OFF the projector and disconnect the AC power cord.
OWER
Section 3.10.6 Adjusting Lamp Position
button (any remote or keypad), turn OFF the projector.
Section 4: Maintenance
4-9