Lamp Hours Not Cleared - Christie D4K Series Troubleshooting Manual

Table of Contents

Advertisement

Details
The BNC female connector on the 3G card has been forced outward by a BNC cable with an
oversized male connector pin. This can cause intermittent or inoperative video due to the loose
connection.
Call log reference number: 411411
Solution
Inspect and replace damaged 3G cards.
Ensure the mating BNC connector pin is not oversized.
Use 75 ohm connectors (not 50 ohm).

Lamp hours not cleared

A new projector does not have the lamp hours factory reset to zero.
Details
Step missed in the production process. There is no problem with the projector or lamp. However, if
the uncleared lamp hours status is considered to be a serious issue, proceed with the solution step
below.
Solution
Replace the MCPU board (P/N: 003-111831-XX). For upgrade instructions, refer to the
Mirage 4K MCPU Board Upgrade Instruction Sheet
MCPU.
D4K and Mirage 4K Troubleshooting Technical Reference
020-101452-03 Rev. 1 (10-2014)
D4K and Mirage 4K Troubleshooting
(P/N: 020-101350-XX) included with the new
D4K-60/
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mirage 4k seriesMirage 4k35Mirage 4k25D4k2560D4k3560

Table of Contents