Others - FE MONITOUCH V8 SERIES Reference: Additional Functions

Table of Contents

Advertisement

Display Limitations
• When the global overlap display has been hidden by the internal command (switch or macro
command) after it was brought up by the external command, bit 3 of the external command must
be set (0 → 1) to display the global overlap display again. It is recommended that you use the
external command to hide the overlap display once it has been shown by the external command.
• Note that the overlap display with "superimpose" is placed over the global overlap display.
• When the global overlap display with "superimpose" is shown, the transparent color and the blend
value become the same as those set for the screen on which the global overlap display first
appeared.
• The global overlap display is not shown while the login screen registered on the [Security Setting]
dialog is displayed.
After the screen display is switched to another, the global overlap display will be shown.
• The global overlap display will be shown again after any of the following functions is executed.
• The macro command CHG_LANG has been executed to change the language.
• The item placed on the global overlap display has been shown/hidden.
• The offset memory value of the item placed on the global overlap display has been changed.
• The overlap display of the same overlap library number has been displayed while the global
overlap display is displayed.
• The data block area cannot be used on the global overlap display. If used in this way, the contents
in the data block area will not be displayed on MONITOUCH.
"Warning" is displayed on the [Error Check] window in the following cases:
• In the case where [Designate: Internal] is selected and the macro command "SET_MOVLP" is
used or [Designate: External] is selected:
Do not specify the overlap library number of the data block area for the global overlap display.
• In the case of the [Function: Multi-Overlap Display] switch with [Designate: Internal] selected:
Change the overlap library number, or delete the data block area from the specified overlap
library.
• When the global overlap display is used, "3" cannot be specified for [Order INC] in the [Detail] tab
window in the [Data Block Area] dialog. Specify a value from 0 to 2 for [Order INC].
• The global overlap display cannot be set for component parts. It cannot be called up from
component parts.