FE MONITOUCH V8 SERIES Reference: Additional Functions page 312

Table of Contents

Advertisement

Example
• MES READ ($u0000, 10, 0)
Return address
The above program searches the database in the computer specified in network table No. 10.
The search is performed according to the settings in the [Read] and [Search condition] tab
windows under MES setting No. 0.
When the search has been completed normally, the returned value 0 and the obtained data are
stored in memory at the addresses starting from the return address $u0000.
Supplementary information
• With $s514, you can set the execution style of the macro. For more information, refer to the V8
Series Connection Manual.
• The result of the macro execution is stored in memory at $s515.
-40: The [Read] tab window setting is not made in the specified MES setting number, or any
setting error is found.
For information on other error numbers, refer to the V8 Series Connection Manual.
• The returned value will not be placed at the address [F1] immediately. The [F1] address can be
monitored by the event timer macro, etc.
• If no [Search condition] tab window setting is made in the specified MES setting number, all
records will be the results of the search.
MES setting No. 0
Network table No. 10
20
MES Interface Function
20-23
20