Appendix 2 Error
Additional Errors
The following errors are added.
For details on other error numbers, item numbers, and sub item numbers, refer to the V8 Series
Reference Manual provided separately.
Error No.
Error No.
127
MONITOUCH does not support the remote
desktop function.
A key code is not registered on MONITOUCH.
*1
128
129
The remote desktop program is not registered in
MONITOUCH.
138
The remote desktop table is not registered.
139
The setting value for the remote desktop table is
incorrect.
166
The function set for the serial port is duplicated.
185
(V806 only)
No optional unit is installed.
186
(V806 only)
No optional unit is installed.
196
The data stored on the CF card is not correct.
199
The function set for the USB port is duplicated.
A key code for the remote desktop is not
*2
214
registered on MONITOUCH.
216
A data sheet includes an item that cannot be
printed.
*1 Version 5.4.13.0 (system program version 1.560 or earlier)
*2 Version 5.4.14.0 (system program version 1.570 or later)
Error: xxx (xx: xx)
Item number
Error number
Problem
Sub item number
Check whether MONITOUCH is a model on
which the remote desktop function can be used.
If not, remove the setting.
Register the license key code for remote
desktop on the Main Menu screen.
Update the V-SFT version and resend the
screen data to MONITOUCH. For data transfer
to a CF card, you need to write the data to the
CF card via the CF card manager.
Register the remote desktop table with the
specified number.
Check the remote desktop setting again
(whether an unregistered remote desktop table
number is specified, etc.).
Error: 166 (0: x)
The sub item number shows;
0: CN1
1: MJ1
2: MJ2
Specify a unique function (Simulator, etc.) for
each port.
Select [System Setting] → [Edit Model
Selection] → [Option Unit], check the setting
and then install option unit "DU-10".
Remove the option unit "DU-10" once and install
it again.
This error may occur when the data (screen, 3D
part, etc.) storing function is used for a CF card.
Insert a CF card on which data is correctly
stored using the CF card manager.
Select one of the following setting for the USB B
port and perform data transfer again.
• USB simulator
• PictBridge printer
• Ladder transfer via USB
Register the license key code for remote
desktop on the Main Menu screen.
Recheck the data sheet screen. Remove the
unusable item.
Appendix 2
Error
Solution
Sub item number
App2-1
A2

Advertisement

Table of Contents
loading