11
Scroll Bar
[Detail] tab window
Process Cycle
(High Speed, Low
Speed, Refresh)
ID
(0 to 255)
Limitations
• Scrolling is performed in dots.
• A JPEG file with an XGA (1024 × 768 dots) resolution can be displayed at the maximum.
• In the case of alarm tracking, only alarm messages can be scrolled horizontally. The date and time
fields cannot be scrolled.
• In the case of the recipe mode, as many rows and columns as displayed can be scrolled in units of
a row or a column.
• If multiple scroll bars provided with the same ID, which do not link to items, are placed, the scroll
bar at the front takes effect.
11-4
Set the same
ID numbers.
Set a cycle for the PLC to read the PLC data while it is communicating with
the V8 series. For more information, refer to "Appendix 5 Process Cycle" in
the V8 Series Reference Manual.
Set the same number as the ID number of the JPEG display item.