• For DSS Console setting, follow the procedures below:
1) Determine the port which you will connect to the DSS Console.
2) Enter an OUS command to change the port to "Out of Service". (This step is not
required if the port status is Fault or already in the OUS mode.)
3) Remove the port by entering a REMOVE command.
4) Assign the Pair Extension in the DSS Console screen first. If other assignments
are required, continue programming.
5) Connect the DSS Console.
6) Enter an INS command to change the port status to "In Service".
• You must remove the port first to set the DSS Console. The default of all the extension
ports is assigned as PITS or SLT. Please note that this DSS Console screen cannot
be opened unless a port is removed.
Changing the DSS Console port to a PITS port
To change the DSS Console port to a PITS port, follow the procedure below:
1) Enter an OUS command to change the port to "Out of Service". (This step is not
required if the port status is Fault or already in the OUS mode.)
2) Remove the DSS Console port by entering a REMOVE command.
3) Assign a DN for the PITS port in the DN Assignment screen (see 10-C-3.00).
4) Assign parameters for the PITS port in the Station screen (see 10-G-1.00).
5) Connect the PITS.
6) Enter an INS command to change the port status to "In Service".
Assigns the type of DSS console used.
Assigns the DSS Console and paired extension's directory number.
A DSS Console does not work without this assignment.
Assigns the type of each of the programmable feature buttons.
When presetting each PF button to "ONETOUCH", set the number.
This assignment is not necessary when the PF key type is preset to any
other types than "ONETOUCH" or "—" appears in the setting field.
Assignable DSS Console types differ depending on the card types
connected to the extensions, as follows:
DSS Console Type Assignable
Card Type
Analog DSS Console
PLC / HLC
Digital DSS Console
DLC
Analog / Digital DSS Console*
DHLC
1
*
When a port is set the mode "XDP" to "Yes" in an Extension Station
(1/4), you cannot assign a DSS Console.