42.00 CPC Signal Detect Timing
(CPC)
Description
CPC command is used to make CPC (Calling Party Control) signal detection
effect on incoming and outgoing CO calls.
Refer to Section 3-F-7.00 "Calling Party Control (CPC) Signal Detection" for
further information.
(Password level: Three or higher)
Input Format
Mode
C
P
C
Index Number
Index Number
10101 to 31416
Item Number Input Values
Item
Assigning Items
Number
None
CPC signal detect timing
(for outgoing CO calls)
CPC signal detect timing
None
(for incoming/outgoing
CO calls)
Index Number
CR
00 : CPC signal is not detected
01 : 6.5 ms
02 : 16 ms (8 N ms N=2 to 75)
75 : 600 ms
(Default = 00)
(Assignable when the card type is RCOT, PCOT, LCOT,
GCOT or T-1 (LCO or GCO channel type))
00 : CPC signal is not detected
01 : 80 ms
02 : 160 ms (80 N ms N=2 to 15)
75 : 1200 ms
(Default = 02)
(Assignable when the card type is DID, DID-2W, DID-MFC
or E-1 (DR2 channel type))
11-C-69
Explanation
Physical Number of the Trunk Port
Input Value