1.02 OUS (Out of Service) command
Description
At the operation prompt (OPE>), enter the OUS
command to change the status of the target
device (shelf, card, station etc.) to "Out of
Service" in on-line mode.
Command Format
OPE> OUS + Item No.
(Item)
Device
Input Value
Shelf
1 to 3 (physical number)
Card
101 to 314 (physical number)
Port
10101 to 31416 (physical number)
Station
DNxxxx (xxxx: extension number;
three or four digits) or Physical
number: five digits
ATT
A1 or A2 or
Physical number: five digits
DTMF
Rxxxy (xxx:Card number; y: 1 or 2)
CNF
CFBxx or CFOyy (xx: 01 to 08,
yy: 01 to 64)
Refer to Section 16-E-3.00 "TST command
(Test)" for details about the test command.
Conditions
The status of target devices (shelf, card, station)
should be "INS", and the system must be in on-
line communication mode.
When you change the status of an upper device
(shelf, card), the status of lower devices (port,
station) change as follows.
Upper device
INS
Lower device
INS
Fault
Normal operation
When this operation is executed without failure,
"OPE>" initial prompt appears again on the
screen.
Operation failed
An error message appears on the screen in the
following cases.
If the system administration terminal is an
Attendant Console (ATT), do not change the
status of the following devices from "INS" to
"OUS".
During remote operation, do not change the
status of the following devices from "INS" to
"OUS".
OUS
OUS
Fault
16-C-2
• Parameter error
• Not installed
• Status error
• Shelf in which ATLC card is installed
• ATLC card
• Attendant console assigned as the
Maintenance Terminal
• Shelf in which RMT card is installed
• RMT card (Modem)