1.02 OUS (Out of Service) Command
Description
Changes the status of the target device (shelf,
card, station etc.) to "Out of Service" in on-line
communication mode.
Conditions
The status of target devices (shelf, card, port,
station) should be "INS".
If the system administration terminal is an
Attendant Console (ATT), do not change the
status of the following devices from "INS" to
"OUS".
• Shelf in which ATLC card is installed
• ATLC card
• Attendant console assigned as the System
Administration Terminal
During a remote operation, do not change the
status of the following devices from "INS" to
"OUS".
• Shelf in which RMT card is installed
• RMT card (Modem)
Operation
Press the function key OUS.
CMD>Out of Service No. = xxxx
1
2
Enter the number of the desired device. Four
input values, see below:
Device
Shelf
1 to 3 (physical number)
Card
101 to 314 (physical number)
Port
10101 to 31416 (physical number)
Station
DNxxxx (xxxx: extension number;
three or four digits) or Physical
number: five digits
ATT
A1 or A2 or
Physical number: five digits
DTMF
Rxxxy (xxx:Card number; y: 1 or 2)
CNF
CFBxx or CFOyy (xx: 01 to 08,
yy: 01 to 64)
Refer to Section 15-F "Functional Test by
Entering Commands" for details about the test
command.
When you change the status of an upper device
(shelf, card), the status of lower devices (port,
station) changes as follows.
Upper device
Lower device
Normal operation
The following message appears on the screen.
***** OK
Operation failed
An error message appears on the screen in the
following cases.
• Parameter error
• Not installed
• Status error
15-C-3
3
Input Value
INS
OUS
INS
OUS
Fault