MIMAKI Tx500-1800B Operation Manual page 180

Hide thumbs Also See for Tx500-1800B:
Table of Contents

Advertisement

Message
E R ROR 6 1 c
N E G A T I V E P . CON T RO L
E R ROR 6 1 d
N E G A T I V E P . N o t E n o u g h
E R ROR 6 1 e
N E G A T I V E P .
O V E R
E R ROR 6 1 f
P O S I T I V E P . CON T RO L
E R ROR 6 2 0
P O S I T I V E P . N o t E n o u g h
E R ROR 6 2 1
P O S I T I V E P .
O V E R
E R ROR 6 2 7
I N S E R T C A R T R I DG E
E R ROR 6 3 7
I N K L E A K 1 - -
E R ROR 6 4 9
N E G A T I V E P . A D J U S T
E R ROR 7 0 2
T H E RM I S T OR
E R ROR 7 0 7
! H 1 H E A T E R B R E A K
E R R O R 9 0 1
シ ゛ ッコウ テ ゛ キマセン
E R ROR 9 0 2
D A T A R EMA I N
E R ROR 9 0 d
NO H E A D S E L E C T
E R ROR 9 1 0
E N V I RONME N T T EMP ( L O )
E R ROR 9 1 1
E N V I RONME N T T EMP ( H I )
5-18
Cause
Starting of the negative pressure con-
trol has an abnormality.
The negative pressure cannot be kept
properly
Starting of the positive pressure control
has an abnormality.
The positive pressure cannot be kept
properly.
There is a slot in which the ink bottle
has not been inserted more than a cer-
tain time.
The ink leakage is detected in the ink
supply path.
Pressure needs to be adjusted.
The thermistor of a heater is defective.
A head heater is disconnected.
You have executed the operation that
cannot be performed.
There remains received data that has
not yet been printed.
The number of mounted heads is 0
(zero).
The ambient temperature is out of the
usable temperature range (too low).
The ambient temperature is out of the
usable temperature range (too high).
Solution
• Perform "PRESSURE ADJUST" (
the maintenance. If you cannot adjust it to the
normal value, or, even if you perform, it may be
displayed, contact your local distributor to call
for service.
Set an ink bottle.
• Turn off the main power to the machine and
turn it on after a while.
If the same error message appears again, con-
tact your local distributor to call for service.
• Perform "PRESSURE ADJUST" (
the maintenance. If you cannot adjust it to the
normal value, or, even if you perform, it may be
displayed, contact your local distributor to call
for service.
Turn off the main power to the machine and turn
it on after a while.
If the same error message appears again, con-
tact your local distributor to call for service.
Execute the data clear function.
(
P.2-38)
• Turn off the main power to the machine and
turn it on after a while.
• If the same error message appears again, contact
your local distributor to call for service.
• Adjust the ambient temperature of the installa-
tion place.
P.5-8) of
P.5-8) of