Error messages

When an error message is displayed, eliminate the error according to the chart below.
If the same error message appears again, contact your dealer or an office of MIMAKI to call for service.
Message
E R ROR 1 0 8
H D CON N E C T [ 1 2 3 4 5 6 7 8 ]
E R ROR 1 0 8
H D T H E RM I S [ 1 2 3 4 5 6 7 8 ]
E R ROR 1 2 a
H D C S P E E D
E R ROR 1 2 e
H e a d F a i l d
/ HDC [ x x x x ]
E R ROR 1 2 2
CH E C K : S DR AM
E R ROR 1 2 8
HDC F I F O OV E R
E R ROR 1 2 8
HDC F I F O UND E R
E R ROR 1 2 9
B A T T E R Y E X CH A NGE
E R ROR 1 3 0
HD D A T A S EQ
E R ROR 1 4 6
E - L OG S E Q
E R ROR 1 5 1
M a i n P C B V 1 2 R
E R ROR 1 5 2
M a i n P C B V 2 R 5
E R ROR 1 5 3
M a i n P C B V 3 R 3
E R ROR 1 5 4
M a i n P C B V 0 5
E R ROR 1 5 5
M a i n P C B V 3 6 - 1
E R ROR 1 5 6
M a i n P C B V 5 B
E R ROR 1 5 7
M a i n P C B V T T
E R ROR 1 5 8
M a i n P C B V 3 6 - 2
Cause
Head connection can not be confirmed.
Head temperature can not be read.
Abnormality of the ink discharge wave-
forms.
Abnormality of the Driver of the Print
head.
There is no PRAM.
Data transmission speed is too fast.
Control circuit board is defective.
Data transmission speed is too slow.
Control circuit board is defective.
The battery life end of the internal clock
is detected.
Head data transferring sequence error
occurred.
Sequential number abnormality of the
event log occurred.
An error occurred in the main PCB
1.2V power supply.
An error occurred in the main PCB
2.5V power supply.
An error occurred in the main PCB
3.3V power supply.
An error occurred in the main PCB 5V
power supply.
An error occurred in the main PCB 36-
1 power supply.
An error occurred in the main PCB 5VB
power supply.
An error occurred in the main PCB VTT
power supply.
An error occurred in the main PCB 36-
2V power supply.
Warning / Error Messages
Solution
• Turn off the power to the machine and turn it on
after a while.
If the same error message appears again, con-
tact your local distributor to call for service.
• Contact your local distributor to call for service.
• Turn off the power to the machine and turn it on
after a while.
If the same error message appears again, con-
tact your local distributor to call for service.
1
1
1
1
5
5-15