8
Pour remover on the belt so that it goes through the cloth.
• Pour remover so that the drop does not drip off on the floor surface while the belt goes
• Be careful not to accrete kerosene (diesel oil) on the belt encoder roller in the right side of
• For the attached remover as standard, the used amount is about 5 liters. For Polix resin SX,
• If remover drops from the belt, wipe it off completely with a waste cloth etc. Discard a waste
• If remover dropped on the belt heater or the main heater, immediately turn OFF the power
9
Rotate the belt until adhesive becomes soft and gelled.
10
Remove the doctor and wipe off adhesive on
the doctor with the waste cloth immersed in
remover.
• This is cleaning to coat adhesive. Perform this before
peeled adhesive cures again.
11
Using the prepared resin board, peel off
adhesive from the belt.
4-36
round once. If remover may adhere to other parts such as washing unit etc., it may adhere
to adhesive again and cause the fixation fault.
this machine (front and rear, total 2 positions).
kerosene (diesel oil) shall be about one liter as the rough standard.
cloth with remover perfused after dehydrating it.
supply and contact a distributor in your district or our office to call for service.