MIMAKI Tx500-1800B Operation Manual page 171

Hide thumbs Also See for Tx500-1800B:
Table of Contents

Advertisement

6
Press the
• Sensor adjustment starts.
7
Rotate the adjustment screw of the throttle valve to
adjust the pressure so that it becomes the proper
value.
• Proper value of negative pressure: -4.00kPa
Proper value of positive pressure: 15.00kPa
• As the negative pressure changes between ±0.1kPa, adjust so that the intermediate value may become
the target pressure.
• Pressure is informed with the buzzer and the ink bottle lamp as well as the screen
• For the negative pressure, the buzzer stops within the range of ±0.1kPa. For the
• Status of lamp and buzzer for each pressure value
Pressure
Positive pressure
~ 8.49
8.50 ~ 9.49
9.50 ~ 10.49
High
10.50 ~ 11.49
11.50 ~ 12.49
12.50 ~ 13.49
13.50 ~ 13.49
Proper
14.50 ~ 15.49
value
15.50 ~ 16.49
16.50 ~ 17.49
17.50 ~ 18.49
18.50 ~ 19.49
Low
19.50 ~ 20.49
20.50 ~ 21.49
21.50 ~ 22.49
22.50 ~ 23.49
23.50 ~
8
Press the
• The error is released and the negative pressure control starts.
• When an error occurs even after you adjusted the pressure, contact your local distributor to call for
service.
key.
display.
positive pressure, the buzzer stops within the range of ±1.0kPa.
Ink bottle lamp Buzzer
Negative pressure
~ -3.35
-3.36 ~ -3.45
-3.46 ~ -3.55
-3.56 ~ -3.65
-3.66 ~ -3.75
-3.76 ~ -3.85
-3.86 ~ -3.95
-3.96 ~ -4.05
-4.06 ~ -4.15
-4.16 ~ -4.25
-4.26 ~ -4.35
-4.36 ~ -4.45
-4.46 ~ -4.55
-4.56 ~ -4.65
-4.66 ~ -4.75
-4.76 ~ -4.85
-4.86 ~
key.
Troubleshooting
* * AD J US T I NG * *
P L E A SE WA I T
PRES SURE
: - 4 . 0 0 k P a
Current pressure
value.
Ink bottle lamp
Sounds
Stops
Stops
Stops
Sounds
P L E A SE WA I T
( - 4 . 0 0 )
Target pressure
value
1
1
1
1
5
5-9

Advertisement

Table of Contents
loading

Table of Contents