HEATERS AND MANUAL AIR CONDITIONING
INSPECTION
Check for bending or abnormal deflection of the rotating
l
shaft of the blower motor assembly.
Check for cracking or deterioration of the packing.
l
Check for damage to the fan.
l
Check for damage to the blower case.
l
Check the operation of the inside/outside air selection
l
damper, and for damage.
BLOWER MOTOR ASSEMBLY CHECK
When battery voltage is applied between the terminals, check
to be sure that the motor operates. Also, check to be sure that
there is no abnormal noise.
SERVICE POINTS OF INSTALLATION
Before installing the blower motor assembly, carefully clean
away any dust, dirt, etc. adhering to the inner surface of the
blower case.
7. INSTALLATION OF AIR SELECTION CONTROL WIRE
Connect the air selection control wire to the air selection
damper lever by following the steps below.
(2) Set the air selection damper lever as it contacts
stopper.
(3) Connect the inner cable of the air selection control wire
to the end of the air selection lever, and then secure the
outer cable by using a clip.