ELECTRIC STARTING SYSTEM
Install firmly the protective rubber on the terminal starter
motor.
Install the drainage tube of the carburetor.
Install the breather tube from the casing of the engine.

MAGNETIC START SWITCH

INSPECTION
NOTE
Prior to inspect the switch magnetic to start,
check the status of the battery.
Remove the cover right side (page 2-2).
Place the transmission in neutral.
Place the power switch in the position ON, and the switch of
emergency in the position RUN.
Press the button breaker to start.
The coil will be normal if the switch breaker magnetic start
cast a characteristic sound ( click ).
In the event that do not listen to the sound, inspect the switch
magnetic start in accordance with the following procedures.
Earth circuit
Release the connector 4P breaker magnetic start.
Check to see if there is a continuity between the terminal of
the cable Green/ Red (circuit of earth) and the earth.
If there is a continuity when the transmission is at a standstill
or when the clutch is decoupled and switch the bracket is
collected, this indicates that the circuit of earth is normal (at a
standstill there is a small resistance, due to the diode).