Defaults
30 seconds
Command Modes
INTERFACE
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 7.6.1.0
Version 7.4.1.0
dot1x tx-period
Configure the intervals at which EAPOL PDUs are transmitted by the Authenticator PAE.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
dot1x tx-period seconds
To return to the default, use the no dot1x tx-period command.
Parameters
seconds
Defaults
30 seconds
Command Modes
INTERFACE
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 7.6.1.0
Version 7.4.1.0
show dot1x interface
Display the 802.1X information on an interface.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
show dot1x interface interface
Parameters
interface
1322
Introduced on the Z9000.
Introduced on the S4810.
Introduced on the C-Series and S-Series.
Introduced on the E-Series.
Enter the interval time, in seconds, that EAPOL PDUs are transmitted.
The range is 1 to 31536000 (1 year). The default is 30.
Introduced on the Z9000.
Introduced on the S4810.
Introduced on the C-Series and S-Series.
Introduced on the E-Series.
Enter one of the following keywords and slot/port or number
information:
•
For a Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed by the slot/port information.
•
For a Fast Ethernet interface, enter the keyword
FastEthernet followed by the slot/ port information.