9-2

Maintenance

Known Harmful Ingredients
The following chemicals are known to damage the plastics on Omron Microscan products and should
not come in contact with the device:
• Acetone
• Ammonia solutions
• Aqueous or alcoholic alkaline solutions
• Aromatic and chlorinated hydrocarbons
• Benzene
• Undiluted Bleach
• Carbolic acid
• Compounds of amines or ammonia
• Ethanolamine
• Ethers
• Ketones
• TB-lysoform
• Toluene
• Trichloroethylene
Tolerable Industrial Fluids and Chemicals
Not all fluid variants and brands have been tested.
The industrial fluids and chemicals listed below were evaluated and deemed tolerable for the housing
of the V460-H. These industrial fluids and chemicals should not come in contact with the V460-H reader
window, which uses technology much like a digital camera. Marks, oil, or debris on the window will interfere
with image captures. Leaving the following industrial fluids on the window will result in suboptimal decode
performance. See
• Motor/Engine Oil
• Automatic Transmission Fluid (ATF)
• Continuously Variable Transmission (CVT) Fluid
• Industrial De-Greaser (Engine Brite Heavy Duty)
• Brake Fluid (DOT4)
If the reader comes in frequent contact with the fluids and chemicals listed above, Omron Microscan
recommends that you clean the outside of the reader daily with the approved cleaning agent listed below.
Approved General Cleaning Agents
The following cleaning agents are approved for general cleaning of Omron Microscan products, including
the V460-H.
• Isopropyl alcohol 70%
V460-H Industrial Handheld DPM Reader User Manual
Cleaning the Reader
for detailed cleaning instructions.