5-1-3
Symbol Type
Serial Cmd:
Default:
Options:
Disabled
When this feature is disabled, only the current enabled symbologies will be considered during the
calibration process.
Enabled
When this feature is enabled, autodiscrimination is in effect during the calibration process. All
supported symbologies except PDF417 and Pharmacode will be attempted during calibration. Any
new symbologies successfully decoded during calibration will remain enabled at the end of the process.
All enabled symbologies will remain enabled. For example, assume that only Code 39 is enabled at the
beginning of calibration. If a Code 128 symbol is decoded during calibration, then Code 128 as well as
Code 39 will be enabled.
5-1-4
Window of Interest (WOI) Margin
Definition:
Serial Cmd:
Default:
Options:
V460-H Industrial Handheld DPM Reader User Manual
<K529,gain,exposure,focus position,symbol type,WOI framing,WOI
margin,line scan height,processing>
Enabled
0 = Disabled
Sets the margin size that is applied to the calibrated symbol. This parameter
is expressed in number of pixels. If the margin causes the image to exceed
the maximum image size, it will be reduced accordingly.
<K529,gain,exposure,focus position,symbol type,WOI framing,WOI
margin,line scan height,processing>
75 (pixels)
20 to 1280
5 Reader Parameters
1 = Enabled
5
5-5