5 Reader Parameters
Matchcode Type
Definition:
Serial Cmd:
Default:
Options:
Disabled:
Enabled:
Wild Card:
Sequential:
5-4-2
Sequential Matching
Usage:
Definition:
Serial Cmd:
Default:
Options:
5-28
Allows the user to choose the way that master symbols will be compared
with subsequently read symbols.
Note: First set Triggering Mode to External or Serial.
<K223,matchcode type,sequential matching,match start position,
match length,wild card character,sequence on No-Read,sequence on
mismatch,placeholder character>
Disabled
0 = Disabled
1 = Enabled
2 = Wild Card
3 = Sequential
Has no effect on operations.
Instructs the reader to compare symbols or portions of symbols with the
master symbol.
Allows the user to enter user-defined wild card characters in the master
symbol.
Instructs the reader to sequence after each match (numeric only) and
compare symbols or portions of symbols for sequential numbers.
Note: If Matchcode Type is set to Sequential, the reader will behave
as if Number of Symbols were set to 1, regardless of the user-defined
configuration.
Useful in tracking product serial numbers that increment or decrement
sequentially.
With Sequential enabled, Sequential Matching determines if a count is in
ascending (incremental) or descending (decremental) order.
<K223,matchcode type,sequential matching,match start position,match
length,wild card character,sequence on No-Read,sequence on mismatch,
placeholder character>
Increment
0 = Increment
1 = Decrement