6 Interface Parameters
Interpretation of K Command Settings:
• Custom Ethernet Link Enabled Default, Transport Layer = UDP;
• Type = Client;
• Capabilities = Send;
• IP Address = 192.168.188.5;
• Port = 5050
Multicast
Server Mode
The following uses the default Multicast IP Address generated in the device.
Send/Receive Capabilities
<K166,1,2,0,3>
Interpretation of K Command Settings:
• Custom Ethernet Link Enabled Default, Transport Layer = Multicast;
• Type = Server Default;
• Capabilities = Send/Receive Default
Send-Only Capabilities
<K166,1,2,0,2>
Interpretation of K Command Settings:
• Custom Ethernet Link Enabled Default, Transport Layer = Multicast;
• Type = Server Default;
• Capabilities = Send
Client Mode
The following client modes will connect to a Multicast server with IP Address 224.0.1.90 listening on
port 5050.
Send/Receive Capabilities
<K166,1,2,1,3, ,224.0.1.90,5050>
Interpretation of K Command Settings:
• Custom Ethernet Link Enabled Default, Transport Layer = Multicast;
• Type = Client;
• Capabilities = Send/Receive Default;
• IP Address = 224.0.1.90;
• Port = 5050
Send-Only Capabilities
<K166,1,2,1,2, ,224.0.1.90, ,5050>
Interpretation of K Command Settings:
• Custom Ethernet Link Enabled Default, Transport Layer = Multicast;
• Type = Client;
• Capabilities = Send;
• IP Address = 224.0.1.90;
• Port = 5050
6-10
V460-H Industrial Handheld DPM Reader User Manual