Omron V460-H User Manual page 67

Industrial handheld dpm reader
Hide thumbs Also See for V460-H:
Table of Contents

Advertisement

3 Basic Operation
Triggered Modes
In Triggered mode, the handheld starts with a trigger, and the cycle ends when the handheld finds the
expected number of codes, or when the read cycle times out.
The cycle time includes the capture and decode times.
• Timeout After is the amount of time the handheld is allowed to spend for the entire read cycle,
acquiring and processing images until all codes are read. You should set this value long enough to be
able to decode in all circumstances, but short enough to prevent the handheld from taking longer
than the allowed cycle time of the production line. (20 msec to 655 seconds. The default is 1 second.
1,000 milliseconds = 1 second.)
Start / Stop
In Start/Stop mode, the handheld goes into Continuous Read mode when you press the trigger, and
exits Continuous Read mode when you release the trigger.
Symbol data is output as soon as possible. The output condition can be configured in Advanced
Parameters (I/O > Symbol Data Output).
Serial Trigger Non-Delimited Off – When Serial Trigger is set to Off, the handheld will respond to the
I/O trigger External Level. High will start the read cycle and low will end it.
Serial Trigger Non-Delimited On – When Serial Trigger is set to On, the handheld will respond to
Serial Triggers. It will also respond to the I/O trigger External Level. By default, the start and stop
characters are set to S and E.
• Serial Tigger Delimited – Sets whether I/O or Serial Trigger and I/O mode are used.
• Start/Stop Characters – Characters used for Serial Trigger. The maximum number of start characters
is 2. The maximum number of stop characters is 2. The character range is 0x00 - 0x7F.
3-26
V460-H Industrial Handheld DPM Reader User Manual