Image Processing Timeout
Usage:
Definition:
Serial Cmd:
Default:
Options:
Notes:
• The timeout period does not include capture time.
• If a timeout occurs during processing and no symbols in the field of view have been decoded, the
image will be recorded as a No-Read. For this reason, a longer timeout should be tried to ensure
that the symbol is decoded successfully.
V460-H Industrial Handheld DPM Reader User Manual
Useful in higher speed applications where image processing time is long
enough that not all captures have an opportunity to be processed.
Specifies the maximum amount of time to process a captured image.
When the timeout expires, the image processing is aborted. This timeout
works in both Rapid Capture and Continuous Capture modes, as well
as with the Configuration Database.
<K245,image processing timeout>
750 ms
1 to 65535 (in 1 ms increments)
5 Reader Parameters