4 WebLink
Configuration
HH
The Stored Image Type field allows the user to configure which images get stored to the destination
device. Options are:
Good Read: Saves image(s) where the decoder reports a good read.
No Read: Saves image(s) where the decoder does not report a good read (default).
Good Read and No Read: Save both Good Read and No Read decoder reports.
Match: Save reports satisfying Match criteria.
Mismatch: Save reports satisfying Mismatch criteria.
Match and Mismatch: Save reports satisfying both Match and Mismatch criteria.
All: Save All reports.
The Storage Mode field represents which image or images are stored. Options are:
First image in a read cycle: Save first image that qualifies the Stored Image Type (default).
All images in a read cycle: Save all images that qualify the Stored Image Type.
Image File Format allows the user to select which file format to apply to the saved image. Options are:
PNG – High Resolution: Save images using PNG format (default).
JPG – Low Resolution: Save images using JPG format.
Image Quality represents a sliding scale between 1% and 100%, where the higher the image quality, the
more space is required per saved image. The default setting is 90%.
4-96
V460-H Industrial Handheld DPM Reader User Manual