4 WebLink
Configuration
HH
Send/Receive Capabilities
<K166,1,0,1,3,192.168.188.5, ,5050>
Interpretation of K Command Settings: Custom Ethernet Link Enabled (Default), Transport Layer =
TCP (Default), Type = Client, Capabilities = Send/Receive (Default), IP Address = 192.168.188.5, Port =
5050.
Send-Only Capabilities
<K166,1,0,1,2,192.168.188.5, ,5050>
Interpretation of K Command Settings: Custom Ethernet Link Enabled (Default), Transport Layer =
TCP (Default), Type = Client, Capabilities = Send, IP Address = 192.168.188.5, Port = 5050.
UDP
Server Mode
Send/Receive Capabilities
<K166,1,1,0,3>
Interpretation of K Command Settings: Custom Ethernet Link Enabled (Default), Transport Layer =
UDP, Type = Server (Default), Capabilities = Send/Receive (Default).
Send-Only Capabilities
<K166,1,1,0,2>
Interpretation of K Command Settings: Custom Ethernet Link Enabled (Default), Transport Layer =
UDP, Type = Server (Default), Capabilities = Send.
Client Mode
The following client modes will connect to a UDP Server with IP Address 192.168.188.5 listening on port
5050.
Send/Receive Capabilities
<K166,1,1,1,3,192.168.188.5, ,5050>
Interpretation of K Command Settings: Custom Ethernet Link Enabled (Default), Transport Layer =
UDP, Type = Client, Capabilities = Send/Receive (Default), IP Address = 192.168.188.5, Port = 5050.
Send-Only Capabilities
<K166,1,1,1,2,192.168.188.5, ,5050>
Interpretation of K Command Settings: Custom Ethernet Link Enabled (Default), Transport Layer =
UDP, Type = Client, Capabilities = Send, IP Address = 192.168.188.5, Port = 5050.
Multicast
Server Mode
The following uses the default Multicast IP Address generated in the device.
Send/Receive Capabilities
<K166,1,2,0,3>
4-143