HH
Standard mode allows you to match total or partial barcodes by defining strings in the Match String
Database.
Wildcard mode allows you to create custom matches using wildcards and placeholders. A wildcard is a
single character that can act as 0 or more characters. A placeholder is a character that can substitute for
exactly one character.
Sequential mode instructs the reader to sequence after each match and to compare symbols or portions
of symbols for sequential numbers.
Standard Mode
Select Match All under Settings for Match String.
Under Match String Database, input the exact decoded data as it appears when you scan the barcode.
Match All is working correctly if it successfully matches a barcode of the same length and character
sequence that you input in the Match String Database.
Now select Partial Match under Settings for Match String. Choose a start position and length based on
the barcode you're scanning.
Partial Match works by using the Start and Length fields and attempting to match the exact portion of text
defined in the Match String Database in that location.