Omron V460-H User Manual page 68

Industrial handheld dpm reader
Hide thumbs Also See for V460-H:
Table of Contents

Advertisement

3-3-5
Configure Acquire Settings
Acquire settings allow you to set Exposure (signified by the sun icon), Gain (signified by the dial and
right-pointing arrow icon), and Focus (signified by the camera icon) in real time. Clicking any of these
settings will cause a control to appear, allowing you to modify that setting. Settings take effect immediately.
The valid Exposure range is 25 µs to 100,000 µs. The valid Gain range is 0% to 100%. The valid
Focus range is 0 mm to 250 mm.
Important: There are 4 levels of Gain in the handheld. Each level corresponds to 25 percentage
points, or one quarter turn of the Gain dial.
• Level 1 = 0% to 24%
• Level 2 = 25% to 49%
• Level 3 = 50% to 74%
• Level 4 = 75% to 100%
When Time of Flight (found in Advanced Settings > I/O or Advanced Acquire Settings) is
enabled or Calculate Exposure and Gain (found in Advanced Settings > Read Cycle or
Advanced Acquire Settings) is enabled, the A shown on the sun icon and dial icon signifies that
Exposure and Gain will be updated automatically based on Time of Flight or Calculate Exposure
and Gain.
V460-H Industrial Handheld DPM Reader User Manual
3 Basic Operation
3-27
3