Omron V460-H User Manual page 223

Industrial handheld dpm reader
Hide thumbs Also See for V460-H:
Table of Contents

Advertisement

4 WebLink
Configuration
HH
<K166,status,transport layer,type,capabilities,IP address,multicast address,port,check
connection,timeout (milliseconds),TTL>
Status of the custom Ethernet object in the device.
0 = Disabled (Default) – The custom Ethernet object is not started.
1 = Enabled – The custom Ethernet object has started with the parameters configured.
Transport Layer
<K166,status,transport layer,type,capabilities,IP address,multicast address,port,check
connection,timeout (milliseconds),TTL>
The transport layer used by the custom Ethernet object to send/receive data. This transport layer obeys
the OSI Model (layer 4). The multicast implementation uses UDP (User Datagram Protocol) as the
transport layer.
0 = TCP (Default)
1 = UDP
2 = Multicast
Type
<K166,status,transport layer,type,capabilities,IP address,multicast address,port,check
connection,timeout (milliseconds),TTL>
This is the how the feature runs on the device and follows the server client model.
0 = Server (Default) – In server mode the device will be listening on the configured port number. The
server can handle up to 10 different connections at one time independent of the transport layer selection.
Once the limit has been reached the server will reject other connections.
For Multicast server configuration the user can either use a specified Multicast address or leave the
Multicast address to the configured Multicast APIPA Address. This Multicast address is safe to use
according to RFC 4607 stating that Multicast ranges from 232.0.0.0 – 232.255.255.255 are okay to use
for source specific applications. By default, the unit creates a unique Multicast address in the range of
232.169.xxx.xxx so it does not conflict with other multicast addresses.
1 = Client – In client mode the device will send data to the specified server. The user must configure the
IP Address (or Multicast Address) of the server and the port number that the specified server is listening
on. Improper configuration will either yield an error on startup or result in no data being transmitted from
the device to the outside world.
Capabilities
<K166,status,transport layer,type,capabilities,IP address,multicast address,port,check
connection,timeout (milliseconds),TTL>
Capabilities is how the user configures the custom Ethernet object's read/write settings.
1 = Receive – The device will only receive data from the connecting endpoint. The device will not send
data out to any connecting endpoints.
2 = Send – The device will only send data to the connecting endpoint. Any data received is immediately
disposed of and not processed.
4-140
V460-H Industrial Handheld DPM Reader User Manual

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

V460-h0px

Table of Contents