5 Reader Parameters
Omron Microscan Symbol Quality Output
5-3-8
Percent Cell Damage (Data Matrix Only)
Definition:
Serial Cmd:
Default:
Options:
5-3-9
Total Read Time
Definition:
Serial Cmd:
Default:
Options:
5-3-10 Capture Time
Definition:
Serial Cmd:
Default:
Options:
5-3-11 Locate Time
Definition:
Serial Cmd:
Default:
Options:
5-3-12 Decode Time
Definition:
Serial Cmd:
Default:
Options:
5-24
When this feature is enabled, the cell damage percentage is appended to
data output.
<K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Disabled
0 = Disabled
The time that transpires between the image capture and the output of the
decoded data, including locate time.
When enabled, the total read time is appended to the symbol data.
<K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Disabled
0 = Disabled
Capture time (in milliseconds) is a fixed "overhead" that includes the time
of capture and transfer of the image.
When enabled, the capture time is appended to the symbol data.
<K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Disabled
0 = Disabled
The time in milliseconds from the start of image processing until the
symbol has been located and is ready to be decoded.
When enabled, the locate time is appended to the symbol data.
<K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Disabled
0 = Disabled
The time in milliseconds required to decode a symbol.
When enabled, the decode time is appended to the symbol data.
<K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Disabled
0 = Disabled
1 = Enabled
1 = Enabled
1 = Enabled
1 = Enabled
1 = Enabled