6 Interface Parameters
6-3-35 Save Image Until
Definition:
Serial Cmd:
Default:
Options:
6-3-36 Action at Image Storage Limit
Definition:
Serial Cmd:
Default:
Options:
6-40
This defines how long the image will be stored in the system when the Image
Storage Location is RAM.
If set to New Read Cycle, the saved image will be erased upon entering the
next read cycle.
If set to System Reset, the saved image will be erased upon the next system
reset.
<K764,image storage location,FTP host info,transfer optimization,RAM
drive size in MB,save image until,action at image storage limit>
New Read Cycle
1 = New Read Cycle
2 = System Reset
This defines what to do when Action at Storage Full is reached and when
images are saved on RAM. When this setting is set to Erase Oldest First, the
oldest images in the current read cycle will be erased.
<K764,image storage location,FTP host info,transfer optimization,RAM
drive size in MB,save image until,action at image storage limit>
Stop
0 = Stop
1 = Erase Oldest First