The timing signal indicating when the output data is stored in PLC memory varies depending on the selected
assembly.
• When using the Small (100) assembly, there is no applicable data output timing signal.
• When using the Big (101) assembly, the timing of data output is when the Device Status - In Read Cycle bit
changes from ON to OFF.
• When MXL/SLC (102) or a later assembly is selected, Output is at the timing when the Data Status Ready
bit of Device Status turns ON.
How does the timing
of EtherNet/IP data
output work?
V460-H Industrial Handheld DPM Reader User Manual
· When using the Small (100) assembly, there is no applicable data output timing signal.
ON
Trigger
OFF
In Read Cycle
Decode Data
· When using the Big (101) assembly, the timing of data output is when Device Status - In Read Cycle
bit changes from ON to OFF.
ON
Trigger
OFF
ON
In Read Cycle
In Read Cycle
OFF
Decode Data
· When MXL/SLC (102) or later assembly is selected. Output is at the timing when the Data Status Ready
bit of Device Status turns ON.
ON
Trigger
OFF
Trigger Ackowledge turns ON when Trigger ON is detected and turns OFF when Trigger OFF is detected.
ON
Trigger
Ackowledge
OFF
Exposure Done turns OFF during exposure and turns ON after exposure completion.
* If you ser Multiple for the number of images to be taken.
Exposure
ON
During
Done
exposure
OFF
Decoding is turned ON during decoding processing (including exposure).
ON
Decoding
During decoding
OFF
ON
Data is Ready
OFF
ON
Read
Cycle Pass
OFF
ON
Read
Cycle Fail
OFF
Decode Data
In Read Cycle
Output data
After storing Decode Data, In Read Cycle turns OFF.
In Read Cycle
Output data
During
exposure
During decoding
Data is Ready turns ON at the same time as Decode Data/Read Cycle Pass/
Read Cycle Fail and turns OFF at the next trigger.
Data output complete
On Good Read
Holds ON state
until Read Start
Output data
8 Troubleshooting
Data output complete
When a No-Read occurs
Holds ON state
until Read Start
Output data
8-7