Omron V460-H User Manual page 235

Industrial handheld dpm reader
Hide thumbs Also See for V460-H:
Table of Contents

Advertisement

4 WebLink
Configuration
HH
1 = Scale Up
2 = Scale Down
3 = Both
Examples:
<K566,0> = Disabled
<K566,1> = Scale Up
<K566,2> = Scale Down
<K566,3> = Both
2D Damaged Mode
2D Damaged Mode allows you to decode symbols with distorted grid alignment or bad cell registration.
If you prefer to use serial commands, the following command allows you to enter your settings via a
Terminal.
Serial Command: <K567,2D Damaged Mode>
Default Setting: Enabled
Options:
0 = Disabled
1 = Enabled
Examples:
<K567,0> = Disabled
<K567,1> = Enabled
Attempt Morphology Manipulation
Attempt Morphology Manipulation applies morphology dilation and attempts to decode. If this isn't
successful, it applies morphology erosion and attempts to decode.
If you prefer to use serial commands, the following command allows you to enter your settings via a
Terminal.
Serial Command: <K568,Attempt Morphology Manipulation>
Default Setting: Disabled
Options:
0 = Disabled
1 = Enabled
Examples:
<K568,0> = Disabled
<K568,1> = Enabled
4-152