Number of Active Indexes
Usage:
Definition:
Serial Cmd:
Default:
Options:
5-6-1
Sort Database
Definition:
Serial Cmd:
Default:
Options:
V460-H Industrial Handheld DPM Reader User Manual
Useful for applications that require several different complex reader configurations
to be applied sequentially. Multiple database indexes allow you to concatenate
configuration profiles, and to perform more complex operations than would
be possible with only one set of configuration parameters.
This feature allows you to set the number of database records (groups of
settings) that will be used automatically during the read cycle. If Number of
Active Indexes is set to 0, only the current reader settings will be used, not
database entry settings.
<K252,number of active indexes,sort database>
0 (Disabled)
0 to 20
Sort Database moves the database entry that produced a successful
decode to the first position in the list of database entries.
<K252,number of active indexes,sort database>
Disabled
0 = Disabled
1 = Enabled
5 Reader Parameters