Symbol Quality Separator/Output Mode
Symbol Quality Separator applies to all Symbol Quality groups: ISO/IEC 16022 Symbol Quality
Output and Omron Microscan Symbol Quality Output.
5-3-2
Symbol Quality Separator
Definition:
Serial Cmd:
Default:
Options:
5-3-3
Output Mode
• Note: Output Mode applies to ISO/IEC 16022 symbol quality parameters.
Definition:
Serial Cmd:
Default:
Options:
Grade
If in Grade Mode, a grade (A,B,C,D,F) is appended to the symbol data.
Value
If in Value Mode, the calculated value for the given parameter is appended to the symbol data.
Score
If in Score Mode, a percentage of passing lines for that parameter is appended to the symbol data.
V460-H Industrial Handheld DPM Reader User Manual
Inserts a separator between each enabled field of the symbol quality output.
<K708,symbol quality separator,output mode>
<SP> (space character)
Any ASCII character.
Output Mode specifies how the output parameters, if enabled, are format-
ted.
<K708,symbol quality separator,output mode>
Grade
0 = Grade
1 = Value
5 Reader Parameters
2 = Score