Timeout After is the amount of time the reader is allowed to spend for the entire read cycle,
acquiring and processing images until all codes are read. You should set this value long enough
to be able to decode in all circumstances, but short enough to prevent the reader from taking
longer than the allowed cycle time of the production line. (20 msec to 655350. The default is 1
second.)
Start / Stop
In Start/Stop mode, the reader goes into Continuous Read mode when you pull the trigger, and exits
Continuous Read mode when you release the trigger, or after 1 second of holding the trigger (by default).
Symbol data is output as soon as possible. The output condition can be configured in Advanced
Parameters (I/O > Symbol Data Output).
Serial Trigger Non-Delimited Off – When Serial Trigger is set to Off, the reader will respond to the I/O
trigger External Level. High will start the read cycle and low will end it.
Serial Trigger Non-Delimited On – When Serial Trigger is set to On, the reader will respond to Serial
Triggers. It will also respond to the I/O trigger External Level. By default, the start and stop characters
are set to S and E.
Serial Tigger Delimited – Sets whether I/O or Serial Trigger and I/O mode are used.
Start/Stop Characters – Characters used for Serial Trigger. The maximum number of start
characters is 2. The maximum number of stop characters is 2. The character range is 0x00 - 0x7F.
V460-H Industrial Handheld DPM Reader User Manual