Omron V460-H User Manual page 372

Industrial handheld dpm reader
Hide thumbs Also See for V460-H:
Table of Contents

Advertisement

Power On/Reset Counts
• Note: Power On/Reset Counts is a read-only command.
Power-On
Serial Cmd:
Power-On uses a 16-bit counter that increments each time the reader is powered-on.
Resets
Serial Cmd:
Resets uses a 16-bit counter that increments each time the reader is reset. This value is reset at
power-on.
Power-On Saves
Serial Cmd:
Power-On Saves uses a 16-bit counter that increments each time an reader setting is saved for power-
on with a <Z> command.
Power-On Flash Saves
Serial Cmd:
Power-On Flash Saves uses a 16-bit counter that increments each time an reader setting is saved to
the customer parameter section of flash memory with a <Zc> command.
V460-H Industrial Handheld DPM Reader User Manual
<K406,power-on,resets,power-on saves,power-on flash saves>
<K406,power-on,resets,power-on saves,power-on flash saves>
<K406,power-on,resets,power-on saves,power-on flash saves>
<K406,power-on,resets,power-on saves,power-on flash saves>