Omron V460-H User Manual page 382

Industrial handheld dpm reader
Hide thumbs Also See for V460-H:
Table of Contents

Advertisement

KIX
When KIX is enabled (<K460,5>), the reader will only decode KIX symbols.
UPU
When UPU is enabled, the reader will decode UPU symbols.
For example, if Postal Symbology Type is set to UPU and POSTNET Status is enabled and
(<K460,6,1>), the reader will attempt to decode both UPU and POSTNET symbols.
7-1-5
POSTNET Status
Usage:
Definition:
Serial Cmd:
Default:
Options:
7-1-6
PLANET Status
Usage:
Definition:
Serial Cmd:
Default:
Options:
V460-H Industrial Handheld DPM Reader User Manual
POSTNET is used by the United States Postal Service to direct mail. The
ZIP Code or ZIP+4 Code is encoded in the symbol. Data is encoded in
half-height and full-height bars, making POSTNET a "2-state" symbology.
The delivery point (usually the last two digits of the address or post office
box number) is also typically encoded in POSTNET symbols.
If U.S. Post and POSTNET Status are both enabled, the reader will
decode POSTNET symbols.
<K460,postal symbology type,POSTNET status,PLANET status,
USPS4CB status>
Enabled
0 = Disabled
1 = Enabled
PLANET (Postal Alphanumeric Encoding Technique) is a symbology
used by the United States Postal Service to track and identify items during
delivery. Each PLANET symbol is either 12 or 14 digits long, and encodes
data in half-height and full-height bars, making PLANET a "2-state" symbology.
The symbol always starts and ends with a full-height bar, or "guard rail",
and each individual digit is represented by a set of five bars in which two of
the bars are always short.
If U.S. Post and PLANET Status are both enabled, the reader will decode
PLANET symbols.
<K460,postal symbology type,POSTNET status,PLANET status,
USPS4CB status>
Enabled
0 = Disabled
1 = Enabled
7 Symbology Parameters
7
7-7

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

V460-h0px