4 WebLink
Configuration
HH
Save Settings to Flash
Save Settings to Flash is a checkbox that determines whether an <A> or a <Z> appears at the end of
the encoded data. An <A> is encoded when it's unchecked, and a <Z> is encoded when it's checked.
Save Settings to Flash also determines whether Restore Defaults uses <Ard> or <Zrd>. <Ard> is
encoded when it's unchecked, and <Zrd> is encoded when it's checked.
Ignore Network Settings
Check Ignore Network Settings to avoid accidentally changing the reader's IP address or name by
reading a programming code containing a different IP address.
Important: If reader settings are not saved, do not change the reader's IP address. The IP address can
be changed after reader settings are saved.
Print Button
When you click the print button, all the barcode groups are shown together. A window is opened that
prompts you to print. The tab closes when you print. Restore Defaults and Differences from Default
appear first, followed by other barcode groups. When there's more than one programming code in a
barcode group, arrows are added to the barcode group to indicate the correct decode direction.