Omron V460-H User Manual page 260

Industrial handheld dpm reader
Hide thumbs Also See for V460-H:
Table of Contents

Advertisement

Serial Data
Usage:
Definition:
Serial Cmd:
• Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a
non-delimited stop serial character has no effect.
Serial Data and Edge
Usage:
Definition:
Serial Cmd:
• Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a
non-delimited stop serial character has no effect.
V460-H Industrial Handheld DPM Reader User Manual
Serial Data is effective in a highly controlled environment where the host
knows precisely when the object is in the field of view. It is also useful in
determining if a No-Read has occurred.
In Serial Data, the reader accepts an ASCII character from the host or
controlling device as a trigger to start a read cycle. A Serial Data trigger
behaves the same as an External Edge trigger.
Serial commands are entered inside angle brackets, as shown here: <t>.
<K200,4>
Serial Data or External Edge is seldom used but can be useful in an
application that primarily uses an external sensing device but occasionally
needs to be triggered manually.
In this mode the reader accepts either a serial ASCII character or an external
trigger pulse to start the read cycle.
<K200,5>
5 Reader Parameters
5-13