1 Product Overview
Step 1 – Connect Hardware
You will need:
1. Ethernet Cable for V460-H-to-PoE Injector Connection
2. PoE Injector (IEEE 802.3af-compliant)
3. Ethernet Cable for PoE Injector-to-Host Connection
4. Host PC
See
Section 2-1 System Configuration
Step 2 – Change IP Address (If Required by Application)
The V460-H's default IP Address is 192.168.188.2 (subnet 255.255.0.0).
If it is necessary to redefine the reader's parameters to match the current network configuration, use the Device
Discovery Utility (DDU). The DDU can be downloaded from automation.omron.com.
The V460-H's IP Address parameters must match those of the PC's Ethernet adapter.
See
Section 3-3 WebLink
Important: IP settings are not modified until they are saved by clicking the Save to Flash Memory icon in
WebLink
. After the Save to Flash Memory icon is clicked, the reader automatically reboots and the new IP
HH
address is now accessible by web browser. The IP setting in WebLink
Memory icon changes from red to blue as shown below.
Save to Flash Memory
If you cycle power to the reader after changing IP settings but before clicking the Save to Flash Memory icon, the
changes will not be saved.
1-4
for a hardware connection diagram.
for detailed information about how to use the DDU.
Quick Start
HH
Saved to Flash Memory
also matches. The Save to Flash
HH
V460-H Industrial Handheld DPM Reader User Manual