Agilent Technologies 8590 Series Service Manual page 637

Analyzers assembly-level repair
Table of Contents

Advertisement

Related Assemblies
A7 analog interface, A16 processor/video assembly, A17 memory card,
A25 counter lock, assemblies installed in the card cage.
Troubleshooting Hints
Refer to
Figure
9-1, IF/Control Overall Block Diagram, and
Figure
9-3, or
Figure
analyzer, in
Chapter 9
the I/O bus. Refer also to
Assembly"
in
Chapter 5
related assemblies.
• If a failure code for an I/O bus address or data line occurs, remove
the related assemblies one at a time until the failure message
disappears. Be sure to turn the analyzer power off while removing
and installing each assembly.
If the failure message disappears, suspect the assembly that was
removed last.
If the failure message remains after all related assemblies have
been removed, suspect the A16 assembly.
• If a A16 video RAM fail code occurs, the A16 assembly is defective.
File type incompatible (U)
Indicates that the selected file is not a display image file. The file name
for a display image file is always preceded by an "i."
Chapter 14
9-4, RF Section Overall Block Diagram for your
for an overview of the assemblies attached to
"Troubleshooting the A15 Motherboard
for the location of specific I/O signal traces on
Analyzer Messages
Interpreting Analyzer Messages
Figure
9-2,
637

Advertisement

Table of Contents
loading