Agilent Technologies 8590 Series Service Manual page 597

Analyzers assembly-level repair
Table of Contents

Advertisement

1
Calculated coarse-tune DAC (0-4095)
2
Sampler harmonic number
3
Calculated sampler IF in Hz
4
Wide-band discriminator sensitivity factor
5
Actual frequency error in Hz on last count
6
Actual measured sampler IF in Hz
7
Actual coarse tune DAC number (0-4095)
8
Main coil sensitivity in number of bits per Hz
9
Actual fine tune DAC number (0-4095)
Spans >10 MHz, changes from sweep to sweep
Spans ≤10 MHz, relatively stable from sweep to
sweep
10
Actual extra-fine tune DAC number (0-4095)
11
Indicates which DAC is being adjusted in the
iteration process; coarse, fine, or extra-fine.
12
Last iterations of the extra-fine tun DAC.
Spans > 10 MHz, readout is in frequency
Spans ≤10 MHz, readout is DAC number
13
Extra-fine tune DAC iterations to get to correct
frequency (not present for spans ≤10 MHz)
14
Fine-tune DAC iterations to get to correct frequency
15
Counter timebase
16
Coarse-tune DAC iterations to get to correct
frequency
17
Drift calculation of marker count, a large difference
between the two LO counts indicates drift (only
present when MKR count is enabled)
18
Discriminator sensitivity factor
19
Sampling oscillator frequency in Hz
Refer to
information.
R
S
ELATED
OFTKEYS
Chapter 13
Chapter 6
for additional LO troubleshooting
DISPLAY CAL DATA
Softkey Descriptions
Softkey Descriptions