1 B - 2 4 M A N U A L A I R C O N D I T I O N I N G
CONDITION AND CAUSE
CORRECTION
Heater oudet Tempûâture too low,
check duct work for proper installation
Check blower operatioû.
Inspect TEMP lever and cable for proper
operation.
Ch€ck heater hoses for function
On A, B and G Series check water
control valve as followsi
1, Start engine and allow to warm uP
2. Set control pan€l for MAX mode
3. Feel hose ftom water valve to
Hose should not be hot This indicatÊs
that vacuùm is appli€d to the water
control valve and that the water supply
to the hۉter core is shut off In anY
other position of the control paû€l selector
(mod€) lever, water should flow to the
heater core. If not, ch€ck water control
valve and vacuum suPplY hose.
4. On B Series, C60 Custom Vq
vacuum
should be âpplied ând water flo* shoùld
stop âs ternpemture lever is moved to
maximùm COLD position it any A,/C mode
b. INLET PIPE COOLER than accumulâtor surface
low refrigerant charge.
. Add slight amounts (1/4lbs.) of refrieerant UNTIL
BOTH feel the sâme temperature Allow stabilization time
. Then add l4 oz. (l can) additionâl refrigerânt.
C, INLET PIPE HAS FROST ACCUMULATION'
Accumulaior surface wârûer; proceed as in Step b above.
T H E R M O S T A T I C S W I T C H D I A G N O S I S
1. Install Manifold Gâge Set and set up the vehicle as
described under "Perfolmance Conditions" in "C C O.T
System Diagnostic Procedure".
2. Set the A/C control al NORM mode, LO blower.
.The thermosotic switch should cvclethe compressor
off in 5 minùtes or l€ss. If the compressor operat€s
cortinùously AND the âccujulâtor frosls, this is an
abnormal condition and will lead to evaporator freez€_up
The oroblem iseither loose clam ps âro und thecapillary rube
ro lhe evaporalor inlel pipe or a defeclive switch
. If the comprcssor does not operate' thermostatlc
switch is defective aprcvided that it has been established that
barterv volraee is avâilable al one sltilch terminâl wilh the
A/C
;on"). ihis. ofcourse. resuk5 in no cooling Replace
. The thermostatic switch is pre'set and cânnot be
adiusted. When trouble shooting the refrigerânt system,
reier to "C.C.O.T. A/C System Diâgnostic Procedures"