Troubleshooting With Chassis And Interface Alarm Messages On The Srx550 High Memory Services Gateway; Table 59: Alarms For Services Gateway Chassis Components - Juniper SRX550 Hardware Manual

Highmemoryservicesgateway
Hide thumbs Also See for SRX550:
Table of Contents

Advertisement

SRX550 High Memory Services Gateway Hardware Guide
Troubleshooting with Chassis and Interface Alarm Messages on the SRX550 High
Memory Services Gateway
148
When the services gateway detects an alarm condition, it lights the red or yellow alarm
LED on the front panel as appropriate. For a detailed description of the alarm condition,
issue the
show chassis alarms
There are two classes of alarm messages:
Chassis alarms—Indicate a problem with a chassis component such as the cooling
system or power supply.
Interface alarms—Indicate a problem with a specific network interface.
For more information about the
Troubleshooting for Security Devices
Table 59 on page 148
describes alarms that can occur for a services gateway chassis
component.

Table 59: Alarms for Services Gateway Chassis Components

Component
Alarm Conditions
Boot media
The services gateway
boots from an
alternate boot device.
Gigabit-Backplane
A GPIM has failed.
Physical Interface
Module (GPIM)
CLI command.
command, see
show chassis alarms
.
Action
If the internal flash fails at
startup, the services
gateway automatically
boots itself from the
alternative boot device
(USB storage device).
If you configured your
services gateway to boot
from an alternative boot
device, ignore this alarm
condition.
If you did not configure the
services gateway to boot
from an alternative boot
device, contact JTAC.
Contact JTAC.
See
"Juniper Networks
Technical Assistance
Center" on page 155
Copyright © 2016, Juniper Networks, Inc.
Monitoring and
Alarm Severity
Yellow (minor)
Red (major)