Table 54: Backup Routing Engine Alarms (continued)
Chassis
Component
Alarm Condition
Multibit
The backup Routing Engine
reports a multibit ECC error.
Memory ECC
Troubleshooting the SRX5400 Services Gateway with Alarm Relay Contacts
The craft interface has two alarm relay contacts for connecting the services gateway to external alarm
devices. Whenever a system condition triggers either the major or minor alarm on the craft interface, the
alarm relay contacts are also activated. The alarm relay contacts are located on the upper right of the craft
interface.
Troubleshooting the SRX5400 Services Gateway with the Craft Interface
LEDs
The craft interface is the panel on the front of the services gateway located above the card cage that
contains LEDs and buttons that allow you to troubleshoot the device.
LEDs on the craft interface include the following:
Remedy
Reboot the system with
the board reset button
on the backup Routing
Engine.
If the alarm recurs, open
a support case using the
Case Manager link at
https://www. j u ni p er. n et/support/
or call 1-888-314-5822
(toll free, US & Canada)
or 1-408-745-9500
(from outside the United
States).
Alarm
Severity
Yellow